组网及说明
/
告警信息
/
问题描述
局点:成都太平洋保险
设备: S12608-G 7747P07
问题:设备持续产生以下告警日志,查看手册处理建议是无需处理,但是日志太频繁影响查看正常日志,
%May 19 13:42:42:538 2023 DSW-VM-G1-P-1.AM11 LIPC/4/LIPC_CHECK: The quality of the link is poor. Owner=comsh, VRF=0, local address/port=0/27881, remote address/port=32768/0.
%May 19 13:42:26:506 2023 DSW-VM-G1-P-1.AM11 LIPC/4/LIPC_CHECK: The quality of the link is poor. Owner=comsh, VRF=0, local address/port=0/27881, remote address/port=32768/0.
%May 19 13:42:10:474 2023 DSW-VM-G1-P-1.AM11 LIPC/4/LIPC_CHECK: The quality of the link is poor. Owner=comsh, VRF=0, local address/port=0/27881, remote address/port=32768/0.
%May 19 13:41:54:442 2023 DSW-VM-G1-P-1.AM11 LIPC/4/LIPC_CHECK: The quality of the link is poor. Owner=comsh, VRF=0, local address/port=0/27881, remote address/port=32768/0.
%May 19 13:41:38:410 2023 DSW-VM-G1-P-1.AM11 LIPC/4/LIPC_CHECK: The quality of the link is poor. Owner=comsh, VRF=0, local address/port=0/27881, remote address/port=32768/0.
#
info-center timestamp loghost no-year-date
info-center loghost source LoopBack1
info-center loghost 10.183.24.177
info-center loghost 10.183.24.178
info-center loghost 10.183.99.123
info-center loghost 10.183.99.124
info-center loghost 25.0.15.8 port 8514
info-center loghost 25.0.17.18 port 8514
#
过程分析
已确认该打印没有功能影响,为平台检测机制误打印了,后续考虑改为默认不打印。
现场可以配置[HP]info-centerloggingsuppressmoduleLIPCmnemonicall解决。
解决方法
已确认该打印没有功能影响,为平台检测机制误打印了,后续考虑改为默认不打印。